ASTM

ASTM E966 : 10

Standard Guide for Field Measurements of Airborne Sound Insulation of Building Facades and Facade Elements

Standard Details

1.1 This guide may be used to determine the outdoor-indoor noise reduction (OINR), which is the difference in sound pressure level between the free-field level outdoors in the absence of the structure and the resulting sound pressure level in a room. Either a loudspeaker or existing traffic noise or aircraft noise can be used as the source. The outdoor sound field geometry must be described and calculations must account for the way the outdoor level is measured. These results are used with Classification E1332 to calculate the single number rating outdoor-indoor noise isolation class, OINIC. Both OINR and OINIC can vary with outdoor sound incidence angle.

1.2 Under controlled circumstances where a single façade is exposed to the outdoor sound, or a façade element such as a door or window has much lower transmission loss than the rest of the façade, an outdoor-indoor transmission loss, OITL(θ), or apparent outdoor-indoor transmission loss, AOITL(θ), may be measured using a loudspeaker source. These results are a function of the angle of incidence of the sound field. By measuring with sound incident at many angles, an approximation to the diffuse field transmission loss as measured between two rooms can be obtained. The results may be used to predict interior sound levels in installations similar to that tested when exposed to an outdoor sound field similar to that used during the measurement. The single number ratings of apparent outdoor-indoor transmission class, AOITC(θ), using AOITL(θ) and field outdoor-indoor transmission class, FOITC(θ), using OITL(θ) may be calculated using Classification E1332. These ratings also may be calculated with the data obtained from receiving room sound pressure measurements performed at several incidence angles as discussed in 8.6.

1.3 To cope with the variety of outdoor incident sound field geometries that are encountered in the field, six testing techniques are presented. These techniques and their general applicability are summarized in Table 1 and Figs. 1-6. The room, façade, or façade element declared to be under test is referred to as the specimen.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

General Information

Status : Historical
Standard Type: Main
Document No: ASTM E966 : 10
Document Year: 2010
Pages: 15
  • Section Volume:
  • 04.06 Volume 04.06 Thermal Insulation; Building and Environmental Acoustics
  • 04.06 Volume 04.06 Thermal Insulation; Building and Environmental Acoustics
  • 04.06 Volume 04.06 Thermal Insulation; Building and Environmental Acoustics
  • ICS:
  • 91.120.20 Acoustics in building. Sound insulation

Life Cycle

Historical

Historical

Currently Viewing

Historical
ASTM E966 : 10

Historical

Historical

Historical
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2024 BSB Edge Private Limited.

Enquire now +