logo

Standards Manage Your Business

We Manage Your Standards

CSA

CSA C22.2 NO. 198.1:26

Extruded insulating tubing (Binational standard with UL 224)

Standard Details

Preface This is the harmonized CSA Group and ULSE standard for Extruded Insulating Tubing . It is the fifth edition of CSA C22.2 No. 198.1 and the eighth edition of UL 224. This edition of CSA C22.2 No. 198.1 supersedes the previous edition(s) published in 2021. This edition of UL 224 supersedes the previous edition published on May 5, 2021. This harmonized Standard was prepared by the CSA Group and ULSE Inc. (ULSE). The efforts and support of the Technical Harmonization Committee 15C, Electrical Tubing and Sleeving Products, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This Standard is considered suitable for use for conformity assessment within the stated scope of the standard. This Standard was reviewed by the CSA Subcommittee on Insulation Systems, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard specifies the requirements for insulating tubing that is usually round in cross-section and that consists entirely of extruded compounds whose characteristic constituents are thermosetting, elastomeric, or thermoplastic polymers (see Table 1 for materials and ratings). These requirements also cover heat-shrinkable and crosslinked tubing. 1.2 Tubing is intended for use only in air – in dry and damp locations – as part of the internal wiring of electrical devices and appliances in accordance with CSA C22.1, Canadian Electrical Code, Part 1 (CE Code, Part I) and NFPA 70®, National Electrical Code® (NEC®). It may be used for insulating one or more inadequately insulated conductors, bus bars, motor leads, transformer leads, terminal lugs, or small assemblies of electronic components. Tubing is not intended for use in contact with sharp edges, corners, or projections, or where subject to tension, compression, or repeated flexing. Tubing is not intended for use where it is feasible to employ a standard insulated conductor (appliance-wiring material) intended specifically for the purpose. 1.3 These requirements do not apply to fabric tubing, chemically dilated tubing, polymeric tubing extruded with reinforcement, or tubing intended only for mechanical protection. 1.4 The acceptability of tubing in any particular device or appliance depends upon its acceptability for continued use under the conditions that prevail in actual service. Accordingly, for a particular application, it will in some cases be necessary to employ tubing having features other than or in addition to those specified in these requirements. For example, tubing may be required to have a heavier wall thickness or a flat rather than a round cross-section; it may be required to have inherent resistance to the effects of immersion in water, oil, solvents, or other liquids (or their vapors); it may be required to be used in an environment conducive to the development of fungi and similar organisms.

General Information

Status : ACTIVE
Standard Type: Main
Document No: CSA C22.2 NO. 198.1:26
Document Year: 2026
Pages: 86
Adopted: No

Life Cycle

Currently Viewing

ACTIVE
CSA C22.2 NO. 198.1:26
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2026 BSB Edge Private Limited.

Enquire now +