logo

Standards Manage Your Business

We Manage Your Standards

SAE

SAE AIR5917 : 2020

Procedure for Measurement of Gaseous Emissions from Aircraft Gas Turbine Engines Using Fourier Transform Infrared Analysis

Standard Details

This Aerospace Information Report (AIR) describes the use of FTIR analyzers for measurements of gaseous emissions from aircraft gas turbine engines and combustion rigs. The use of FTIR analyzers can be demonstrated as a suitable and cost-effective equivalent to NDIR and chemiluminescence analyzers as prescribed in ARP1256 for the measurement of CO, CO 2 , NO, and NO 2 , where NO x is closely approximated by the sum of NO and NO 2 concentrations. FTIR analyzers may be proven suitable for equivalency of analyzers used in current emission testing. Additionally, FTIR analyzers have potential for equivalent measurements of “total” hydrocarbon (THC) as currently defined in ARP1256.

Cross Reference:

General Information

Status : Issued
Standard Type: Main
Document No: SAE AIR5917 : 2020
Document Year: 2020
Pages: 29

Life Cycle

Currently Viewing

Issued
SAE AIR5917 : 2020
Knowledge Corner