logo

Standards Manage Your Business

We Manage Your Standards

CSA

C22.2 NO. 66.3-06 (R2020)

Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers (Bi-National standard, with UL 5085-3)

Standard Details

Preface This is the common CSA and UL standard for low voltage transformers. It is the first edition of CSA C22.2 No. 66.3 and the first edition of UL 5085-3. This edition of CSA C22.2 No. 66.3 supersedes the requirements of CSA C22.2 No. 66 published in 1988. This edition of UL 5085-3 supersedes the Fourth edition of UL 1585 published in 1998. Scope 1.1 As noted in Low Voltage Transformers - Part 1: General Requirements, UL 5085-1, or CSA C22.2 No. 66.1, Low Voltage Transformers - Part 1: General Requirements, the requirements in Part 3 cover Class 2 transformers for use with Class 2 circuits in accordance with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, Part I, CSA C22.1. They are intended for connection to essentially sinusoidal supply sources. Advisory Note: For transformers intended for use in the United States, these requirements also cover Class 3 transformers for use with Class 3 circuits in accordance with the National Electrical Code, ANSI/NFPA 70, unless otherwise specified in this standard. See Annex D for Class 3 requirements. 1.3 In addition to the items specified in Clause 1.3 of Part 1, the requirements of Part 3 do not cover: a) Power supplies (a transformer provided with a rectifier is considered a power supply); b) Toy transformers; c) Cord and plug connected transformers; d) Direct plug-in transformers; e) Transformers intended for use in audio, radio, or television type appliances; or f) Other special types of transformers covered in requirements for other electrical devices or appliances. Advisory Note: The requirements of Part 3 do not cover transformers intended for use in the United States having a nominal primary rating of more than 600 V and transformers having overvoltage taps rated over 660 V. 1.7 This part is intended to be used in conjunction with Part 1. The numbering of the clauses in Part 3 corresponds to the numbered clauses in Part 1. The requirements in Part 1 apply unless modified by Part 3. 1.8 A Class 2 transformer that includes a separate current-limiting impedance such as a resistor or a positive temperature coefficient device (PTC) is covered by these requirements. 1.9 A Class 2 transformer that includes a resonance regulating circuit is covered by these requirements.

General Information

Status : ACTIVE
Standard Type: Main
Document No: C22.2 NO. 66.3-06 (R2020)
Document Year: 2006
Pages: 69

Life Cycle

Currently Viewing

ACTIVE
C22.2 NO. 66.3-06 (R2020)
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2024 BSB Edge Private Limited.

Enquire now +