logo

Standards Manage Your Business

We Manage Your Standards

ISO

ISO 15310:1999

Fibre-reinforced plastic composites — Determination of the in-plane shear modulus by the plate twist method

Standard Details

1.1 This International Standard specifies a method for determining the in-plane shear modulus (G12) of fibrereinforced

plastic composites using a standard plate specimen. When applied to isotropic materials, the shear

modulus measured is independent of direction.

1.2 The method is used to determine the shear modulus of the test specimens but not to determine the shear

strength. It applies to a plate supported on two points on one diagonal and loaded on the other diagonal by the

simultaneous movement of two loading points attached to a cross-beam.

1.3 The method is suitable for use with fibre-reinforced plastic composites with both thermoset and thermoplastic

matrices.

Due to the shear deformation being applied under flexural conditions, for laminated materials with different fibre

formats and/or different orientations, the layers of material must be well distributed across the section so that it is

approximately "homogeneous" in the through-thickness direction.

The principal material axes, if present, must be orientated normal to the plate edges (see 3.8).

NOTE This method can be applied to unreinforced polymers and other materials (e.g. metals, ceramics and metal- or

ceramic-matrix composites).

For material fabricated using unidirectional plies, the shear modulus obtained using a multidirectional specimen

(i.e. 0°/90°/_ 45°) is not the same as that obtained for unidirectional or cross-ply (0°/90°) material.

1.4 The method is performed using specimens which may be moulded to the chosen dimensions, machined from

test plates or machined from flat areas of products.

1.5 The method specifies preferred dimensions for the specimen. Tests which are carried out on specimens of

other dimensions, or on specimens which are prepared under different conditions, may produce results which are

not comparable. Other factors, such as the speed of testing and the conditioning of the specimens, can influence

the results. Consequently, when comparative data are required, these factors must be carefully controlled and

recorded.

NOTE The stress-strain response in shear is very non-linear at higher strain levels. This test method determines the

modulus within a low strain region and is not applicable to higher strains.

General Information

Status : Published
Standard Type: Main
Document No: ISO 15310:1999
Document Year: 1999
Pages: 11
Edition: 1
  • ICS:
  • 83.120 Reinforced plastics

Life Cycle

Currently Viewing

Published
ISO 15310:1999
Knowledge Corner

Expand Your Knowledge and Unlock Your Learning Potential - Your One-Stop Source for Information!

© Copyright 2024 BSB Edge Private Limited.