This document is applicable to pressures ranging from 80 kPa to 160 kPa and temperatures ranging from -20 °C to +200 °C.
This document does not apply to the following:
- external safety-related measurement and control equipment that might be required to keep the operational conditions within the established safe limits;
- flame arresters used for explosive mixtures of vapours and gases, which tend to self-decompose (for example, acetylene) or which are chemically unstable;
- flame arresters used for carbon disulfide, due to its special properties;
- flame arresters whose intended use is for mixtures other than gas-air or vapour-air mixtures (for example, higher oxygen-nitrogen ratio, chlorine as oxidant);
- flame arrester test procedures for reciprocating internal combustion engines;
- fast acting valves, extinguishing systems and other explosion isolating systems;
- Flame arresters used in gas detectors (those being covered for example, by IEC 60079‑29‑1 and IEC 62990‑1).
This edition cancels and replaces ISO 16852:2016, which has been technically revised. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to ISO 16852:2016:
a) adaptation of the relevant IEC TC 31 requirements on standards;
b) modification of the upper limit of the temperature range from 150 °C to 200 °C under the condition that T0 shall be not larger than 80 % of the auto ignition temperature of the gas-air-mixture;
c) change of the term "explosion group" to "equipment group" due to editorial requirements in IEC/TC 31;
d) clarification of the conditions and requirements for flame arresters whose intended operating conditions are outside the atmospheric conditions in 7.3.4 and 7.3.5;
e) clarification of the requirements on the information for use in Clause 12 f) concerning the burn time;
f) addition of a permission to the construction requirements both in 7.1 and 14.1 to substitute visual inspection by performing a flow test;
g) addition of a flow chart for the evaluation of test results as Annex D">